Carbon Trends (Apr 2021)

Radiation damage of a two-dimensional carbon fiber composite (CFC)

  • N. Simos,
  • E. Quaranta,
  • N. Charitonidis,
  • D. Sprouster,
  • Z. Zhong,
  • S. Ghose,
  • Z. Kotsina,
  • R. Assmann,
  • S. Redaelli,
  • A. Bertarelli,
  • A.I. Ryazanov

Journal volume & issue
Vol. 3
p. 100028

Abstract

Read online

Carbon fiber composites (CFC) are, among other applications, already in use as low-impedance collimating elements for intercepting TeV-level protons machines, like the CERN Large Hadron Collider. Towards a comprehensive understanding of these materials’ properties and behavior, a series of radiation damage campaigns have been undertaken in order to quantitively investigate the response of AC-150 K CFC to high proton fluences. The CFCs dimensional changes, stability, micro-structural evolution, and structural integrity below and above 5 × 1020 p/cm2 fluence threshold were studied. The irradiating particles were protons of kinetic energies in the range of 130–200 MeV. The effects of the irradiation temperature (~90–180 °C and 280–500 °C) combined with the proton fluence on the dimensional stability and the microstructural evolution of this anisotropic two-dimensional composite structure were studied using precision dilatometry and X-ray diffraction. Our results shed light on the fluence-based limitations for these composite materials. Furthermore, we compare these results with reference unirradiated graphite, and we discuss the similarities and differences in the dimensional changes and post-irradiation annealing properties.