BMC Ophthalmology (Sep 2020)

Comparison of ultrasound cycloplasty and transscleral cyclophotocoagulation for refractory glaucoma in Chinese population

  • Qiuli Yu,
  • Ya Liang,
  • Fangfang Ji,
  • Zhilan Yuan

DOI
https://doi.org/10.1186/s12886-020-01655-y
Journal volume & issue
Vol. 20, no. 1
pp. 1 – 7

Abstract

Read online

Abstract Background To compare the efficacy and safety of focused ultrasound cycloplasty (UCP) and transscleral cyclophotocoagulation (TSCP) in the treatment of refractory glaucoma in a Chinese population. Methods We retrospectively compared twenty-eight eligible patients with refractory glaucoma, who were divided into the UCP group and TSCP group. Patients in these two groups underwent a corresponding procedure from June 2018 to February 2019. The intraocular pressure (IOP), visual acuity, the number of anti-glaucoma agents used and complications were reviewed and compared between groups. Proper statistical methods were selected according to comparison models under IBM SPSS 25 software. Results After the 12-months follow-up, postoperative IOP and number of anti-glaucoma agents used in the two groups were both reduced than the baseline level, and the differences were statistically significant (P 0.05). In terms of complications, the pain at 1 day after surgery in the UCP group was significantly milder than that in the TSCP group (P 0.05). Conclusions Both UCP and TSCP are safe and effective methods for the treatment of refractory glaucoma. Nevertheless, pain is less severe after UCP.