Abstract

Read online

This article presents the results of a durability test of a prototype low-pulsation pump. Hydraulic measurements conducted during the test enabled visualisation of the behaviour of the unit in working conditions. The test was conducted according to a strict factory standard, which states that pump performance parameters cannot decrease by more than 8% during durability testing. The material presented in this publication is the result of a study within the project entitled The development of innovative gear pumps with a reduced level of acoustic emission. The solution developed as part of the project has been successfully implemented for a series of gear pumps consisting of twenty-two units. Among other awards, the product won the Gold Medal at the 10th International Fair of Pneumatics, Hydraulics, Drives and Controls, Kielce 2017.