Energies (May 2024)

Development and Analysis of Six-Phase Synchronous Reluctance Motor for Increased Fault Tolerance Capabilities

  • Cezary Jedryczka,
  • Michal Mysinski,
  • Wojciech Szelag

DOI
https://doi.org/10.3390/en17102351
Journal volume & issue
Vol. 17, no. 10
p. 2351

Abstract

Read online

This paper contains research on the development of a fault-tolerant six-phase synchronous reluctance motor (SynRM) based on the stator adopted from a general-purpose three-phase induction motor. In the design and calculation process, an extended Clarke transformation was developed for a six-phase asymmetrical system. To verify the proposed design approach, a field–circuit model of electromagnetic phenomena in the studied motor was developed and used to study the motor performance. The increased torque value and reduction in torque ripples were confirmed by comparison to the classical three-phase SynRM design. To illustrate fault tolerance capabilities, the operation of the studied three- and six-phase synchronous reluctance motors under inverter-fault conditions was examined. The conducted analysis shows, among other things, that from the electromagnetic performance point of view, only the proposed six-phase machine is able to properly operate under inverter-fault conditions. The results of the winding design calculations, the performed simulations of six-phase motor operation, and the preliminary tests of the prototype motor are presented and discussed.

Keywords