Annals of Intensive Care (May 2020)

Thenar oxygen saturation (StO2) alterations during a spontaneous breathing trial predict extubation failure

  • Jaume Mesquida,
  • Guillem Gruartmoner,
  • Cristina Espinal,
  • Jordi Masip,
  • Caroline Sabatier,
  • Ana Villagrá,
  • Hernando Gómez,
  • Michael Pinsky,
  • Francisco Baigorri,
  • Antonio Artigas

DOI
https://doi.org/10.1186/s13613-020-00670-y
Journal volume & issue
Vol. 10, no. 1
pp. 1 – 7

Abstract

Read online

Abstract Background Weaning from mechanical ventilation (MV) is a cardiovascular stress test. Monitoring the regional oxygenation status has shown promising results in predicting the tolerance to spontaneously breathe in the process of weaning from MV. Our aim was to determine whether changes in skeletal muscle oxygen saturation (StO2) measured by near-infrared spectroscopy (NIRS) on the thenar eminence during a vascular occlusion test (VOT) can be used to predict extubation failure from mechanical ventilation. Methods We prospectively studied 206 adult patients with acute respiratory failure receiving MV for at least 48 h from a 30-bed mixed ICU, who were deemed ready to wean by their physicians. Patients underwent a 30-min spontaneous breathing trial (SBT), and were extubated according to the local protocol. Continuous StO2 was measured non-invasively on the thenar eminence. A VOT was performed prior to and at 30 min of the SBT (SBT30). The rate of StO2 deoxygenation (DeO2), StO2 reoxygenation (ReO2) rate and StO2 hyperemic response to ischemia (H AUC) were calculated. Results Thirty-six of the 206 patients (17%) failed their SBT. The remainder 170 patients (83%) were extubated. Twenty-three of these patients (13.5%) needed reinstitution of MV within 24 h. Reintubated patients displayed a lower H AUC at baseline, and higher relative changes in their StO2 deoxygenation rate between baseline and SBT30 (DeO2 Ratio). A logistic regression-derived StO2 score, combining baseline StO2, H AUC and DeO2 ratio, showed an AUC of 0.84 (95% CI 0.74–0.91) for prediction of extubation failure. Conclusions Extubation failure was associated to baseline and dynamic StO2 alterations during the SBT. Monitoring StO2-derived parameters might be useful in predicting extubation outcome.

Keywords