Journal of Vascular Surgery Cases and Innovative Techniques (Jun 2022)

Coil embolization of ruptured distal renal artery pseudoaneurysm with gross hematuria and hemorrhagic shock

  • Andrea McSweeney, BS,
  • Anand Tarpara, MD,
  • Dawn Salvatore, MD,
  • Paul DiMuzio, MD,
  • Michael Nooromid, MD,
  • Babak Abai, MD

Journal volume & issue
Vol. 8, no. 2
pp. 210 – 213

Abstract

Read online

Renal artery pseudoaneurysms have been infrequently reported in the literature. In the present report, we have described a case of a ruptured renal artery pseudoaneurysm requiring coil embolization. A 49-year-old man had presented to our institution with a hypertensive emergency. Computed tomography revealed a 3.4-cm right renal artery pseudoaneurysm. Nonemergent coil embolization was planned for the following day. However, he became hypotensive, exsanguinating frank blood from the urethra. An arteriogram showed extravasation of contrast into the pseudoaneurysm sac, renal pelvis, and ureter, consistent with intrarenal pseudoaneurysm rupture. We have demonstrated coil embolization as a method of repairing a ruptured renal artery pseudoaneurysm with gross hematuria.

Keywords