Journal of Orthopaedic Surgery and Research (Aug 2024)

Advantages of customization of osseointegrated implants in transfemoral amputees: a comparative analysis of surgical planning

  • Valentina Betti,
  • Giulia Galteri,
  • Stefano Zaffagnini,
  • Domenico Alesi,
  • Kavin Morellato,
  • Marco Palanca,
  • Emanuele Gruppioni,
  • Luca Cristofolini

DOI
https://doi.org/10.1186/s13018-024-04944-0
Journal volume & issue
Vol. 19, no. 1
pp. 1 – 15

Abstract

Read online

Abstract Background Commercially available osseointegrated devices for transfemoral amputees are limited in size and thus fail to meet the significant anatomical variability in the femoral medullary canal. This study aimed to develop a customized osseointegrated stem to better accommodate a variety of femoral anatomies in transfemoral amputees than off-the-shelf stems. Customization is expected to enhance cortical bone preservation and increase the stem-bone contact area, which are critical for the long-term stability and success of implants. Methods A customized stem (OsteoCustom) was designed based on the statistical shape variability of the medullary canal. The implantability of the OsteoCustom stem was tested via 70 computed tomography (CT) images of human femurs and compared to that of a commercial device (OFI-C) for two different resection levels. The evaluations included the volume of cortical bone removed and the percentage of stem-bone contact area for both resection levels. Statistical significance was analyzed using paired and unpaired t tests. Results The OsteoCustom stem could be virtually implanted in all 70 femurs, while the OFI-C was unsuitable in 19 cases due to insufficient cortical thickness after implantation, further emphasizing its adaptability to varying anatomical conditions. The OsteoCustom stem preserved a greater volume of cortical bone than did the OFI-C. In fact, 42% less bone was removed at the proximal resection level (3.15 cm³ vs. 5.42 cm³, p ≤ 0.0001), and 33% less at the distal resection level (2.25 cm³ vs. 3.39 cm³, p = 0.003). The stem-bone contact area was also greater for the OsteoCustom stem, particularly at the distal resection level, showing a 20% increase in contact area (52.3% vs. 32.2%, p = 0.002) compared to that of the OFI-C. Conclusions The OsteoCustom stem performed better than the commercial stem by preserving more cortical bone and achieving a greater stem–bone contact area, especially at distal resection levels where the shape of the medullary canal exhibits more inter-subject variability. Optimal fit in the distal region is of paramount importance for ensuring the stability of osseointegrated implants. This study highlights the potential benefits of customized osseointegrated stems in accommodating a broader range of femoral anatomies, with enhanced fit in the medullary canal.

Keywords