Scientific Reports (Oct 2024)

Correlation between subretinal tissue plasminogen activator and air injection rates with pressure in a retina mimicking model

  • Na Hee Kim,
  • Minsub Lee,
  • Hyewon Chung,
  • Hyung Chan Kim,
  • Hyungwoo Lee

DOI
https://doi.org/10.1038/s41598-024-77518-z
Journal volume & issue
Vol. 14, no. 1
pp. 1 – 8

Abstract

Read online

Abstract By investigating the correlation between the injection rate and pressure of subretinal tissue plasminogen activator (tPA) and air using a standard Viscous Fluid Control (VFC) system with a 38-gauge cannula, we aimed to establish guidelines for stable injections. We fabricated a retina mimicking model (RMM) with 0.25% agarose solution and an aluminum plate, and substituted submacular hemorrhage (SMH) and tPA with blood-mimicking fluid (BMF) and balanced salt solution (BSS), respectively. The diameter of the pre-bleb mimicking SMH in RMM was 1.30 ± 0.16 cm, increasing to 1.98 ± 0.24 cm and 1.83 ± 0.22 cm after bleb propagation with BSS and air, respectively. BSS injection rates were 2.86 ± 0.04 µl/sec, 6.74 ± 0.48 µl/sec and 8.55 ± 0.16 µl/sec at 8, 12, and 16 psi, respectively. Air injection rates were 37.98 ± 3.11 µl/sec, 79.01 ± 5.13 µl/sec and 156.06 ± 13.72 µl/sec at 2, 3 and 4 psi, respectively. By experimenting with different pressures in the RMM, we found 12 psi to be the minimum for proper BSS injection and 2 psi for air. These findings provide crucial parameters for safer surgery to prevent irreversible damage.