Diagnostics (Mar 2023)

Left Atrioventricular Transvalvular Pressure Gradients Derived from Intraoperative and Postoperative Echocardiograms following Atrioventricular Septal Defect Repair

  • Maximilian Bamberg,
  • Mark Simon,
  • Andrea Bandini,
  • Julia Kelley Hahn,
  • Christian Schlensak,
  • Vanya Icheva,
  • Michael Hofbeck,
  • Peter Rosenberger,
  • Harry Magunia,
  • Marius Keller

DOI
https://doi.org/10.3390/diagnostics13050957
Journal volume & issue
Vol. 13, no. 5
p. 957

Abstract

Read online

Background: Left atrioventricular valve (LAVV) stenosis following an atrioventricular septal defect (AVSD) repair is a rare but potentially life-threatening complication. While echocardiographic quantification of diastolic transvalvular pressure gradients is paramount in the evaluation of a newly corrected valve function, it is hypothesized that these measured gradients are overestimated immediately following a cardiopulmonary bypass (CPB) due to the altered hemodynamics when compared to postoperative valve assessments using awake transthoracic echocardiography (TTE) upon recovery after surgery. Methods: Out of the 72 patients screened for inclusion at a tertiary center, 39 patients undergoing an AVSD repair with both intraoperative transesophageal echocardiograms (TEE, performed immediately after a CPB) and an awake TTE (performed prior to hospital discharge) were retrospectively selected. The mean (MPGs) and peak pressure gradients (PPGs) were quantified using a Doppler echocardiography and other measures of interest were recorded (e.g., a non-invasive surrogate of the cardiac output and index (CI), left ventricular ejection fraction, blood pressures and airway pressures). The variables were analyzed using the paired Student’s t-tests and Spearman’s correlation coefficients. Results: The MPGs were significantly higher in the intraoperative measurements when compared to the awake TTE (3.0 ± 1.2 vs. 2.3 ± 1.1 mmHg; p p = 0.06). Although the assessed intraoperative heart rates (HRs) were also higher (132 ± 17 vs. 114 ± 21 bpm; p p < 0.001). During the in-hospital follow-up period, no patients died or required an intervention due to LAVV stenosis. Conclusions: The Doppler-based quantification of diastolic transvalvular LAVV mean pressure gradients using intraoperative transesophageal echocardiography seems to be prone to overestimation due to altered hemodynamics immediately after an AVSD repair. Thus, the current hemodynamic state should be taken into consideration during the intraoperative interpretation of these gradients.

Keywords