Diagnostic performance of a new two-dimensional shear wave elastography expression using siemens ultrasound system combined with ACR TI-RADS for classification of benign and malignant thyroid nodules: A prospective multi-center study
Wei-Hong Qi,
Kun Jin,
Liu-Liu Cao,
Mei Peng,
Nian-An He,
Xiao-Lin Zhan,
Yang Yang,
Yun-Yun Guo,
Xin-Wu Cui,
Fan Jiang
Affiliations
Wei-Hong Qi
Department of Medical Ultrasound, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, 230601, PR China
Kun Jin
Department of Medical Ultrasound, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, 230601, PR China
Liu-Liu Cao
Department of Medical Ultrasound, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, 230601, PR China
Mei Peng
Department of Medical Ultrasound, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, 230601, PR China
Nian-An He
The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 230001, PR China
Xiao-Lin Zhan
Department of Medical Ultrasound, The Fourth Affiliated Hospital of Anhui Medical University, Hefei, Anhui, 230012, PR China
Yang Yang
The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 230001, PR China
Yun-Yun Guo
Department of Medical Ultrasound, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, 230601, PR China
Xin-Wu Cui
Department of Medical Ultrasound, Tongji Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430030, PR China
Fan Jiang
Department of Medical Ultrasound, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, 230601, PR China; Corresponding author.
Objective: The present study aimed to evaluate the efficacy of a new two-dimensional shear wave elastography (2D-SWE) method using a Siemens ultrasound system and its combination with the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) for the differential diagnosis of benign and malignant thyroid nodules. Methods: Conventional ultrasound images and 2D-SWE (E-whole-mean and E-stiffest-mean) were prospectively analyzed in 593 thyroid nodules from 543 patients. Nodules were divided into diameter (D) ≤10 mm and D > 10 mm groups and graded using ACR TI-RADS. The receiver operating characteristic curve was plotted using pathological findings as the gold standard. Diagnostic performance was compared among 2D-SWE, ACR TI-RADS, and their combination. Results: The area under the curve (AUC) for E-whole-mean was higher than that for E-stiffest-mean (0.858 vs. 0.790, P 10 mm groups (P < 0.001). Conclusion: As the better 2D-SWE parameter, E-whole-mean had a higher diagnostic power than ACR TI-RADS and enhanced the diagnostic performance of ACR TI-RADS when identifying benign and malignant thyroid nodules. The combination of E-whole-mean and ACR TI-RADS improved the diagnostic performance compared to using ACR TI-RADS alone, providing a new and reliable method for the clinical diagnosis of thyroid nodules.