IEEE Access (Jan 2021)

Capacitor Lifetime Extension in a Hybrid Active Neutral-Point-Clamped Inverter With Reduction of DC-Link Ripple Current and Common-Mode Voltage

  • Sang-Won An,
  • Seok-Min Kim,
  • Kyo-Beum Lee

DOI
https://doi.org/10.1109/ACCESS.2021.3064859
Journal volume & issue
Vol. 9
pp. 40336 – 40348

Abstract

Read online

This paper proposes a reduction method for DC-link ripple current and common-mode voltage (CMV) in a hybrid active neutral-point-clamped (ANPC) inverter. A Si and SiC hybrid ANPC inverter has been developed recently to overcome the extremely high cost of a full-SiC ANPC inverter. A hybrid ANPC requires much fewer SiC MOSFETs than a full-SiC ANPC inverter while providing a comparable power density. Voltage source inverters such as hybrid ANPC inverters utilize electrolytic capacitors, which have a large capacitance per volume, as a DC link. However, an electrolytic capacitor is one of the most vulnerable components in a power electronic converter due to its small allowable ripple current. A large ripple current flowing into the electrolytic capacitor generates a heat loss, which shortens the lifetime of the capacitor. Furthermore, the common-mode voltage (CMV) causes an undesirable leakage current and electromagnetic interference. The CMV depends on the pulse-width modulation of the voltage source inverters. The proposed method enhances the reliability of the hybrid ANPC inverter by reducing the DC-link ripple current and CMV simultaneously. The effectiveness and validity of the proposed method are verified through simulations and experimental results.

Keywords