International Journal of Metrology and Quality Engineering (Jan 2019)

Characterization of high-precision resistive voltage divider and buffer amplifier for ac voltage metrology

  • Karlsen Bjørnar,
  • Lind Kåre,
  • Malmbekk Helge,
  • Ohlckers Per

DOI
https://doi.org/10.1051/ijmqe/2019006
Journal volume & issue
Vol. 10
p. 8

Abstract

Read online

A high-precision voltage buffer and a 10:1 resistive voltage divider have been constructed for use in ac voltage and electrical power metrology. Long-term stability of the buffer's dc response has been demonstrated by two dc sweeps performed 20 days apart, with best-fit linearized gain varying less than 1 μV/V. The absolute ac gain has been measured using a high-precision digital multimeter for 10 Hz and 1 kHz with results consistent with dc within 5 μV/V. This value agrees with the characterization of ac–dc difference using thermal converters from different producers with a variety of resistance for various voltages from 1 V to 5 V. The ac–dc difference was further characterized better than 40 μV/V for the same voltages up to 100 kHz and better than 100 μV/V for 3 V at 1 MHz. Absolute ac gain and ac–dc difference has also been measured for the voltage divider and buffer combination from 10 V to 50 V, with similar agreement up to 1 kHz. The ac–dc difference from 10 Hz to 100 kHz of this combination shows an agreement well within 30 μV/V in this entire voltage span with a total response not exceeding 125 μV/V. This make the voltage divider and buffer combination suitable for sampling electrical powers for a wide range of voltages.