Journal of Taibah University for Science (Dec 2024)

Dose enhancement of nanogold for prostate radiation: Monte Carlo simulation using the ICRP voxel computational male phantom

  • Wafa M. Al-Saleh,
  • Turki Almatani

DOI
https://doi.org/10.1080/16583655.2024.2340138
Journal volume & issue
Vol. 18, no. 1

Abstract

Read online

Using a male ICRP voxel computational phantom, Monte Carlo simulations were performed to estimate the dose enhancement ratio (DER) in prostate radiation for 6 and 10 MV photon energy. A fully validated linear accelerator head was used, initially with a single beam to calculate the DER for different concentrations of nanogold mixed with prostate tissue. Each energy was tested with (FF) and without (FFF) a flattening filter. The DER was then calculated for a verified 10 MV treatment plan to mimic the real treatment scenario. The results showed that the DER increased with concentration, especially for FFF mode. In addition, the flattening filter-free enhancement ratio (FFFER) was investigated, from which it was found that a 6 MV FFF with a 40 mg/ml concentration enhanced the dose by a factor of 1.03 compared to 6 MV FF. For the entire plan, the difference between FFF and FF for both energies was approximately 2%.

Keywords