Multiple Sclerosis International (Jan 2011)

Optical Coherence Tomography in Multiple Sclerosis and Neuromyelitis Optica: An Update

  • Susana Noval,
  • Inés Contreras,
  • Silvia Muñoz,
  • Celia Oreja-Guevara,
  • Beatriz Manzano,
  • Gema Rebolleda

DOI
https://doi.org/10.1155/2011/472790
Journal volume & issue
Vol. 2011

Abstract

Read online

Optical coherence tomography (OCT) uses light interference patterns to produce a cross-sectional image of the retina. It is capable of measuring the unmyelinated axons of the retinal ganglionar cells as they converge on the optic disc. In a disease like multiple sclerosis (MS), in which axonal loss has been identified as an important cause of sustained disability, it may prove an invaluable tool. OCT has demonstrated that axonal loss occurs after each episode of optic neuritis and that the degree of axonal loss is correlated to visual outcomes. Furthermore, axonal loss occurs in MS even in the absence of inflammatory episodes, and the degree of this loss is correlated with the duration of the disease process, with more thinning as the disease advances and in progressive forms. Thus, OCT retinal nerve fiber layer measurements may represent an objective outcome measure with which to evaluate the effect of treatment.