Nuclear Materials and Energy (Dec 2018)

Wall conditioning throughout the first carbon divertor campaign on Wendelstein 7-X

  • Tom Wauters,
  • Andrei Goriaev,
  • Arturo Alonso,
  • Juergen Baldzuhn,
  • Rudolf Brakel,
  • Sebastijan Brezinsek,
  • Andreas Dinklage,
  • Heinz Grote,
  • Joris Fellinger,
  • Oliver P. Ford,
  • Ralf König,
  • Heinrich Laqua,
  • Dmitry Matveev,
  • Torsten Stange,
  • Lilla Vanó

Journal volume & issue
Vol. 17
pp. 235 – 241

Abstract

Read online

Controlling the recycling of hydrogen and the release of impurities from the plasma facing components proved to be essential and challenging throughout the first divertor campaign on W7-X. This paper discusses the conditioning requirements throughout the first divertor campaign on Wendelstein 7-X. Baking at 150 °C and glow discharge conditioning (GDC) in H2 is performed after the initial pump down of the vacuum vessel. Experimental programs in hydrogen are interlaced with He discharges to desaturate the wall from hydrogen, recover good recycling conditions and hence establish plasma density control. Optimized He ECRH wall conditioning procedures consisted of sequences of short discharges with fixed duty cycle. He-GDC remained however needed before each experimental day to fully offset the hydrogen inventory build-up. A significant increase in the divertor temperature is observed throughout an operational day, enhancing outgassing of CO and H2O. Preliminary recombination-diffusion modelling of hydrogen outgassing suggests enhanced diffusion to deeper surface layers with increasing wall temperature, which results in better wall pumping. This indicates that the experienced plasma performance degradation throughout an operational day results from increased impurity outgassing at higher wall temperature rather than hydrogen saturation of the wall. Keywords: W7-x, stellarator, Wall conditioning, Baking, GDC, RF discharge