PLoS ONE (Jan 2014)

A modified chronic infection model for testing treatment of Staphylococcus aureus biofilms on implants.

  • Nis Pedersen Jørgensen,
  • Rikke L Meyer,
  • Frederik Dagnæs-Hansen,
  • Kurt Fuursted,
  • Eskild Petersen

DOI
https://doi.org/10.1371/journal.pone.0103688
Journal volume & issue
Vol. 9, no. 10
p. e103688

Abstract

Read online

Bacterial biofilms causing implant-associated osteomyelitis is a severe complication with limited antimicrobial therapy options. We designed an animal model, in which implant associated osteomyelitis arise from a Staphylococcus aureus biofilm on a tibia implant. Two bioluminescently engineered (luxA-E transformed), strains of S. aureus were utilized, Xen29 and Xen31. Biofilm formation was assessed with epifluorescence microscopy. Quantitative measurements were performed day 4, 6, 8, 11 and 15 post-surgery. Bacteria were extracted from the biofilm by sonication and the bacterial load quantified by culturing. Biofilm formation was evident from day 6 post-implantation. Mean bacterial load from implants was ∼1×10(4) CFU/implant, while mean bacterial load from infected tibias were 1×10(6) CFU/bone. Bioluminesence imaging revealed decreasing activity throughout the 15-day observation period, with signal intensity for both strains reaching that of the negative control by day 15 while there was no significant reduction in bacterial load. The model is suitable for testing antimicrobial treatment options for implant associated OM, as treatment efficacy on both biofilm and viable counts can be assessed.