Zhongguo shuxue zazhi (Feb 2022)

HIV Ag-Abdetection by ELISA: a retrospective analysis

  • Liangxue WEN,
  • Ling WANG,
  • Li SU,
  • Mingfen WANG

DOI
https://doi.org/10.13303/j.cjbt.issn.1004-549x.2022.02.023
Journal volume & issue
Vol. 35, no. 2
pp. 216 – 218

Abstract

Read online

Objective To conduct a retrospective analysis of HIV Ag-Ab detection by ELISA in our blood center, so as to provide reference for continuous improvement. Methods The reactive rate of HIV by each reagent, reactive rate of both reagents, re-test rate, concordance rate of initial-repeat test, and reagent utilization rate were counted, and the external quality assessment results were analyzed by PT score and z-ratio. Results The total reactive rate of HIV was 0.15%. The reactive rate by both reagents was 0.02%. The re-test rates, reactive rates, concordance rates and reagent utilization rates of the two reagents were 0.09% vs 0.08%, 0.07% vs 0.06%, 75.86% vs 78.21%, and 114.54% vs 113.92%, respectively. PT score was 100%, and z-ratio of 7 negative samples and 1 positive sample was less than 2, and of 2 positive samples was more than 3. Conclusion The laboratory quality monitoring indicators and external quality assessment can effectively monitor the operation of blood testing laboratory.