Mathematical and Computational Applications (Mar 2022)
In Vivo Validation of a Cardiovascular Simulation Model in Pigs
Abstract
Many computer simulation models of the cardiovascular system, of varying complexity and objectives, have been proposed in physiological science. Every model needs to be parameterized and evaluated individually. We conducted a porcine animal model to parameterize and evaluate a computer simulation model, recently proposed by our group. The results of an animal model, on thirteen healthy pigs, were used to generate consistent parameterization data for the full heart computer simulation model. To evaluate the simulation model, differences between the resulting simulation output and original animal data were analysed. The input parameters of the animal model, used to individualize the computer simulation, showed high interindividual variability (range of coefficient of variation: 10.1–84.5%), which was well-reflected by the resulting haemodynamic output parameters of the simulation (range of coefficient of variation: 12.6–45.7%). The overall bias between the animal and simulation model was low (mean: −3.24%, range: from −26.5 to 20.1%). The simulation model used in this study was able to adapt to the high physiological variability in the animal model. Possible reasons for the remaining differences between the animal and simulation model might be a static measurement error, unconsidered inaccuracies within the model, or unconsidered physiological interactions.
Keywords