Journal of Lipid Research (Dec 1982)

All-trans-retinoic acid: measurement of reference values in human serum by high performance liquid chromatography

  • A P De Leenheer,
  • W E Lambert,
  • I Claeys

Journal volume & issue
Vol. 23, no. 9
pp. 1362 – 1367

Abstract

Read online

A quantitative determination of physiological levels of all-trans-retinoic acid (vitamin A acid) in human serum has been developed. A double-phase extraction of 3.5 ml of serum followed by a specific and sensitive high performance liquid chromatography procedure allowed measurement of levels down to 1 ng/ml. Serum concentrations in 37 fasting volunteers ranged from 2.7 to 4.2 ng/ml and fitted a normal-Gaussian distributional shape with a mean value of 3.5 ng/ml and SD of 0.4 ng/ml, as demonstrated by the Kolmogorov-Smirnov test.