Revista Colombiana de Ciencias Pecuarias (Mar 2015)

A simple methodology to measure ammonia flux generated in naturally ventilated poultry houses

  • Jairo Alexander Osorio Saraz,
  • Ilda de Fátima Ferreira Tinoco,
  • Richard S Gates,
  • Keller Sullivan Oliveira Rocha,
  • Olga Lucía Zapata Marín

Journal volume & issue
Vol. 28, no. 1
pp. 3 – 12

Abstract

Read online

Background: quantifying the rate of pollutant emissions, such as ammonia (NH3), from naturally ventilated animal production buildings in structures, such as those used in South America, is challenging mainly due to the challenge of determining building ventilation rate. Some methods have been developed to reduce this difficulty, but most are costly and complex, preventing their implementation.. Objective: the present work aimed to adapt and validate the Saraz method for the determination of ammonia emissions (SMDAE) from naturally ventilated poultry houses. Methods: to validate the proposed method, the ammonia emission rate (ER; NH3 mass emitted per unit time) was computed using the adjusted equation proposed by Wheeler et al.(2006; ER2). For evaluation purposes, the data obtained from the two measuring methods (SMDAE and ER2)were statistically analyzed. Results: the proposed method was considered adequate for use under conditions of natural ventilation with wind speeds greater than 0.1 m/s-1 and NH3 concentrations greater than 1 ppm. Conclusion: the method demonstrated a good correlation between its values and those obtained by the standard equation for calculating emissions based on NH3 concentration, air speed and temperature, which makes the Saraz method a reliable approach to develop ammonia inventories for naturally-ventilated poultry facilities.

Keywords