Prosthesis (Jan 2024)
Investigating the Influence of All-Ceramic Prosthetic Materials on Implants and Their Effect on the Surrounding Bone: A Finite Element Analysis
Abstract
This study aims to assess and compare the impact of Monolithic Zirconia (MZ) and In-Ceram Zirconia (ZP) superstructures on stress distribution within implants and D2/D4 bone densities under 200 N vertical and oblique occlusal loads using three-dimensional finite element analysis via ANSYS WORKBENCH R2. The analysis employed maximum and minimum von Mises stress values. Modeling an implant (4.2 mm diameter, 10 mm length) and abutment (0.47 mm diameter), with an 8 mm diameter and 6 mm length single crown, the research identified lower von Mises stresses in D2 cancellous bone with the MZ model under vertical loading. Conversely, under oblique loading, the ZP model exhibited maximum von Mises stresses in D4 bone around the implant. This underscores the critical need to consider physical and mechanical properties, beyond mere aesthetics, for sustained implant success. The findings highlight the effect of material composition and stress distribution, emphasizing the necessity of durable and effective implant treatments.
Keywords