Open Research Europe (Oct 2023)

X-ray beam quality after a mirror reflection: Experimental and simulated results for a toroidal mirror in a 4th generation storage-ring beamline [version 1; peer review: 2 approved]

  • Juan Reyes-Herrera,
  • Marco Cammarata,
  • Rafael Celestre,
  • Matteo Levantino,
  • Raymond Barrett,
  • Manuel Sanchez del Rio

Journal volume & issue
Vol. 3

Abstract

Read online

Background The surface errors found in X-ray mirrors constitute a limiting factor for preserving beam quality. This is particularly important when the X-ray beam has low emittance and a significant coherence fraction, like in newly upgraded synchrotron storage rings. Methods We studied the fringes observed in the image of an undulator-produced X-ray beam reflected by a high-quality toroidal mirror. The measurements and simulations were performed using different conditions: a photon beam either monochromatic or with large bandwidth, reflected by a mirror with variable curvature. Results The experimental data are compared with up-to-date simulation including partial coherence. Conclusions The observed fringes in the unfocused beam correlate with low spatial frequency structures in mirror profiles, irrespective of beam coherence. Both classical ray tracing and partially coherent simulations through coherent mode decomposition are confirmed as accurate methods for such simulations.

Keywords