Frontiers in Cardiovascular Medicine (Aug 2023)

Safety, accuracy, and prediction of prognosis in patients with end-stage chronic kidney disease undergoing dobutamine stress cardiac magnetic resonance imaging

  • Lukas D. Weberling,
  • Lukas D. Weberling,
  • Sebastian Seitz,
  • Sebastian Seitz,
  • Janek Salatzki,
  • Janek Salatzki,
  • Andreas Ochs,
  • Andreas Ochs,
  • Ailís C. Haney,
  • Deborah Siry,
  • Jannick Heins,
  • Henning Steen,
  • Henning Steen,
  • Norbert Frey,
  • Norbert Frey,
  • Florian André,
  • Florian André

DOI
https://doi.org/10.3389/fcvm.2023.1228691
Journal volume & issue
Vol. 10

Abstract

Read online

IntroductionAdvanced chronic kidney disease (CKD) is an independent risk factor for coronary artery disease (CAD). Due to its unique uremia-derived pathophysiology of atherosclerosis and the limitations of using potentially harmful contrast agents, the best non-invasive approach to assess CAD in these patients remains unclear. We sought to investigate the accuracy, safety, and prognosis of patients with severe CKD undergoing dobutamine stress cardiac magnetic resonance imaging (CMR).Materials and methodsIn this retrospective, single-center study, patients on dialysis or with a glomerular filtration rate of <15 ml/min/1.73 m2 who underwent dobutamine stress CMR were included. A rest and stress wall motion analysis was performed using dobutamine/atropine as stressor. The target heart rate was 85% of the maximum heart rate. Periprocedural adverse events and 1-year follow-up data were obtained.ResultsA total of 176 patients (127 men, 49 women) with a mean age of 60.9 ± 14.7 years were included, of which 156 patients were on permanent dialysis. Short-term symptoms such as angina or shortness of breath during stress CMR were frequent (22.1%), but major complications were rare (one patient with myocardial infarction, 0.6%). The 1-year event rate was high (16.4%) with a significant independent correlation to reduced ejection fraction at rest (p = 0.037) and failure to achieve the target heart rate (p = 0.029). The overall accuracy for predicting significant CAD was good (sensitivity of 71.4%, specificity of 98.4%) and excellent if the target heart rate was achieved (83.3%, 97.9%). A negative stress CMR was highly predictive for the absence of major adverse cardiac event or any coronary revascularization during the 1-year follow-up (negative predictive value of 95.0%).DiscussionDobutamine stress CMR is a safe and accurate diagnostic imaging technique in patients at advanced stages of chronic kidney disease. A reduced ejection fraction and the inability to reach the target heart rate are independent predictors of a poor outcome.

Keywords