Journal of Cardiovascular Development and Disease (Feb 2024)

Radiation Exposure and Contrast Agent Use during Endovascular Aortic Repair Using Mobile Versus Fixed Angiography Systems

  • Amir Arnautovic,
  • Waseem Garabet,
  • Reinhold Thomas Ziegler,
  • Joscha Mulorz,
  • Sönke Maximilian Braß,
  • Alexander Oberhuber,
  • Hubert Schelzig,
  • Markus Udo Wagenhäuser,
  • Philip Dueppers

DOI
https://doi.org/10.3390/jcdd11030083
Journal volume & issue
Vol. 11, no. 3
p. 83

Abstract

Read online

Background: For (thoracic) endovascular aortic repair ((T)EVAR) procedures, both mobile (standard operating room (SOR)) and fixed C-arm (hybrid operating room (HOR)) systems are available. This study evaluated differences in key procedural parameters, and procedural success for (T)EVAR in the SOR versus the HOR. Methods: All patients who underwent standard elective (T)EVAR at the Clinic for Vascular and Endovascular Surgery at the University Hospital Duesseldorf, Germany, between 1 January 2012 and 1 January 2019 were included. Data were retrieved from archived medical records. Endpoints were analyzed for SOR versus HOR during (T)EVAR. Results: A total of 93 patients, including 50 EVAR (SOR (n = 20); HOR (n = 30)) and 43 TEVAR (SOR (n = 22); HOR (n= 21)) were included. The dose area product (DAP) for EVAR and TEVAR was lower in the SOR than in the HOR (EVAR, SOR: 1635 ± 1088 cGy·cm2; EVAR, HOR: 7819 ± 8928 cGy·cm2; TEVAR, SOR: 8963 ± 34,458 cGy·cm2; TEVAR, HOR: 14,591 ± 11,584 cGy·cm2 (p p p p ≥ 0.05). Conclusion: The use of a fixed C-arm angiography system in the HOR results in higher radiation exposure and longer fluoroscopy times but lower contrast agent volumes when compared with mobile C-arm systems in the SOR. Because stochastic radiation sequelae are more likely to be tolerated in an older patient population and, in addition, there is a higher incidence of CKD in this patient population, allocation of patients to the HOR for standard (T)EVAR seems particularly advisable based on our results.

Keywords