Molecules (Nov 2018)

Essential Oils from <i>Humulus Lupulus</i> scCO<sub>2</sub> Extract by Hydrodistillation and Microwave-Assisted Hydrodistillation

  • Katarzyna Tyśkiewicz,
  • Roman Gieysztor,
  • Marcin Konkol,
  • Jan Szałas,
  • Edward Rój

DOI
https://doi.org/10.3390/molecules23112866
Journal volume & issue
Vol. 23, no. 11
p. 2866

Abstract

Read online

Two different extraction methods were used for a comparative study of essential oils obtained from the Humulus lupulus scCO2 (sc-supercritical) extract: microwave-assisted hydrodistillation (MAHD) and conventional hydrodistillation (HD). As a result, the best conditions for the maximum essential oil production were determined for the MAHD method at 335 W microwave power for 30 min at water to raw material ratio of 8:3. The obtained essential oils were enriched in β-myrcene in the amount of 74.13%⁻89.32% (wt%). Moreover, the first application for determination of the above-mentioned volatile compounds by supercritical fluid chromatography (SFC) with photo-diode array detection (PDA) is presented, which in comparison with gas chromatography coupled with mass spectrometry (GC-MS/MS) resulted in similar values for β-myrcene and α-humulene in obtained samples within less than 1 min.

Keywords