Dataset for NiO/ZnO biomorphic nanocomposite using a poplar tree leaf template to generate an enhanced gas sensing platform to detect n-butanol
Qing-rui Zeng,
Jun-tong Feng,
Xin-chen Lin,
Yue Zhao,
Hang Liu,
Sheng-zhe Wang,
Zhao-jun Dong,
Wei Feng
Affiliations
Qing-rui Zeng
Key Laboratory of Groundwater Resources and Environment, Ministry of Education, College of New Energy and Environment, Jilin University, Changchun 130021, PR China
Jun-tong Feng
Dalian Yuming Senior High School, Dalian 116023, PR China
Xin-chen Lin
Key Laboratory of Groundwater Resources and Environment, Ministry of Education, College of New Energy and Environment, Jilin University, Changchun 130021, PR China; School of Environment, Harbin Institute of Technology, Harbin 150090, PR China
Yue Zhao
Key Laboratory of Groundwater Resources and Environment, Ministry of Education, College of New Energy and Environment, Jilin University, Changchun 130021, PR China
Hang Liu
Key Laboratory of Groundwater Resources and Environment, Ministry of Education, College of New Energy and Environment, Jilin University, Changchun 130021, PR China
Sheng-zhe Wang
Key Laboratory of Groundwater Resources and Environment, Ministry of Education, College of New Energy and Environment, Jilin University, Changchun 130021, PR China
Zhao-jun Dong
Key Laboratory of Groundwater Resources and Environment, Ministry of Education, College of New Energy and Environment, Jilin University, Changchun 130021, PR China
Wei Feng
Key Laboratory of Groundwater Resources and Environment, Ministry of Education, College of New Energy and Environment, Jilin University, Changchun 130021, PR China; Corresponding author.
The SEM image data presented in this article was collected by the Scanning electron microscopy (SEM) performed on an XL-30 ESEM FEG scanning electron microscopy. The diameter stastics data was collected and calculated by the Image-Pro Plus software system. The UV–Vis Res spectrum was collected by solid state UV diffuse reflector Shimadzu UV-4100 at wavelength 200–800 nm. The SEM image data showed more details of the poplar tree leave template(PTLT). The diameter stastics data show the diameter averagely distributed in the material. The UV–Vis Res spectrum reflected the physical property of PTLT NiO/ZnO. Interpretation of this data can be found in a research article titled “One-step facile synthesis of a NiO/ZnO biomorphic nanocomposite using a poplar tree leaf template to generate an enhanced gas sensing platform to detect n-butanol” (Qingrui Zeng et al., 2019) [1], Research Article DOI: 10.1016/j.jallcom.2019.05.018