Change-over natural and mechanical ventilation system energy consumption in single-family buildings

E3S Web of Conferences. 2017;22:00086 DOI 10.1051/e3sconf/20172200086

 

Journal Homepage

Journal Title: E3S Web of Conferences

ISSN: 2267-1242 (Online)

Publisher: EDP Sciences

LCC Subject Category: Geography. Anthropology. Recreation: Environmental sciences

Country of publisher: France

Language of fulltext: French, English

Full-text formats available: PDF

 

AUTHORS

Kostka Maria
Szulgowska–Zgrzywa Małgorzata

EDITORIAL INFORMATION

Editorial review

Editorial Board

Instructions for authors

Time From Submission to Publication: 6 weeks

 

Abstract | Full Text

The parameters of the outside air in Poland cause that in winter it is reasonable to use a mechanical ventilation equipped with a heat recovery exchanger. The time of spring, autumn, summer evenings and nights are often characterized by the parameters of the air, which allow for a natural ventilation and reduce the electricity consumption. The article presents the possibilities of energy consumption reduction for three energy standards of buildings located in Poland, ventilated by a change–over hybrid system. The analysis was prepared on the assumption that the air–to–water heat pump is the heat source for the buildings.