International Journal of Nanomedicine (Jan 2024)

A One Step Strategy Based on Hollow Gold Nanoparticles to Detect C-Reactive Protein with High Sensitivity (Hs-CRP) in Serum for Monitoring Cardiovascular Disease

  • Luo C,
  • Zhang R,
  • Liu J,
  • He X,
  • Li S,
  • Ran C,
  • Ma S,
  • Shen Y

Journal volume & issue
Vol. Volume 19
pp. 845 – 858

Abstract

Read online

Changyou Luo,1,* Ruiqing Zhang,2,* Ji Liu,1,* Xingyue He,1 Shengzhou Li,1 Chuanjiang Ran,1 Songbo Ma,3 Yan Shen1 1Department of Pharmaceutics, China Pharmaceutical University, Nanjing, 211100, People’s Republic of China; 2Children’s Hospital of Nanjing Medical University, Nanjing, People’s Republic of China; 3Department of Oral and Maxillofacial Surgery, The Affiliated Taizhou People’s Hospital of Nanjing Medical University, Taizhou, Jiangsu, 225300, People’s Republic of China*These authors contributed equally to this workCorrespondence: Yan Shen; Songbo Ma, Email [email protected]; [email protected]: Rapid detection and diagnosis of diseases facilitate timely and effective treatment of cardiovascular diseases (CVD). The establishment of a one-step rapid detection method provides a new method for the initial screening and disease risk assessment of patients with cardiovascular diseases in primary medical units.Methods: Hollow gold nanoparticles (HGNPs) were synthesized using a cobalt template method followed by use as signal amplification probes for ultra-sensitive quantitative detection of serum C-reactive protein (CRP). To induce the localized surface plasmon resonance (LSPR) and improve protein labeling efficiency, we developed a sensitive detection mode by coating polyvinylpyrrolidone (PVP-K30) on the HGNPs, resulting in a significant improvement in detection performance.Results: Compared to traditional colloidal GNP-based LFTA, PVP-coated HGNPs exhibit a lower visual detection limit of 1 ng/mL, which a 25-fold decrement compare to using GNPs as the antibody-labeled probe, and the detection limit could be reduced to 0.14 ng/mL under the quantitative instrument.Conclusion: The one-step method based on HGNP immunochromatographic strips modified with PVP established in this study can be used for the detection of CRP and hs-CRP in biological samples. The performance of the immunochromatographic technique designed in this study was evaluated from the perspective of synthetic markers, and the application conditions of this strip were screened, verifying its high specificity, indicating that it has high sensitivity and strong detection limit compared to colloidal gold. The sensitivity of the hollow gold immunochromatographic test strip in this article has been increased by about 25 times, providing a new method for rapid detection of CVD in clinical diagnosis.Keywords: C-reactive protein, lateral flow immunoassay, hollow gold nanoparticles, in vitro diagnostics, polyvinylpyrrolidone

Keywords