Sensors (May 2019)
Fire Control System Operation Status Assessment Based on Information Fusion: Case Study
Abstract
In traditional fault diagnosis strategies, massive and disordered data cannot be utilized effectively. Furthermore, just a single parameter is used for fault diagnosis of a weapons fire control system, which might lead to uncertainty in the results. This paper proposes an information fusion method in which rough set theory (RST) is combined with an improved Dempster–Shafer (DS) evidence theory to identify various system operation states. First, the feature information of different faults is extracted from the original data, then this information is used as the evidence of the state for a diagnosis object. By introducing RST, the extracted fault information is reduced in terms of the number of attributes, and the basic probability value of the reduced fault information is obtained. Based on an analysis of conflicts in the existing DS evidence theory, an improved conflict evidence synthesis method is proposed, which combines the improved synthesis rule and the conflict evidence weight allocation methods. Then, an intelligent evaluation model for the fire control system operation state is established, which is based on the improved evidence theory and RST. The case of a power supply module in a fire control computer is analyzed. In this case, the state grade of the power supply module is evaluated by the proposed method, and the conclusion verifies the effectiveness of the proposed method in evaluating the operation state of a fire control system.
Keywords