Journal of Petroleum Exploration and Production Technology (Nov 2017)

Transient flowing-fluid temperature modeling in reservoirs with large drawdowns

  • N. Chevarunotai,
  • A. R. Hasan,
  • C. S. Kabir,
  • R. Islam

DOI
https://doi.org/10.1007/s13202-017-0397-0
Journal volume & issue
Vol. 8, no. 3
pp. 799 – 811

Abstract

Read online

Abstract Modern downhole temperature measurements indicate that bottomhole fluid temperature can be significantly higher or lower than the original reservoir temperature, especially in reservoirs where high-pressure drawdown is expected during production. This recent finding contradicts the isothermal assumption originally made for routine calculations. In a high-pressure drawdown environment, the Joule–Thomson (J–T) phenomenon plays an important role in fluid temperature alteration in the reservoir. This paper presents a robust analytical model to estimate the flowing-fluid temperature distribution in a reservoir that accounts for the J–T heating or cooling effect. All significant heat transfer mechanisms for fluid flow in the reservoir, including heat transfer due to convection, J–T phenomenon, and heat transfer from overburden and under-burden formations, are incorporated in this study. The proposed model successfully validates the results of a rigorous numerical model that intrinsically honored field data.

Keywords