Nuclear Fusion (Jan 2024)
CIGALE: an innovative gas neutralizer based high efficiency neutral beam injector concept for future fusion reactors
Abstract
This paper outlines the main features of a new high efficiency ( η > 62%) high power (∼18 MW D ^0 ) neutral beam (NB) concept based on pragmatic solutions suitable with the reactor requirements. The injector is modular (several beamlines in parallel) with independent ion sources referenced to the ground potential and gas neutralizers held at +1 MV. This topology leads to numerous simplifications; it overcomes the main issues of conventional NB systems, such as the complex 1 MV electrical setup, the difficult ion source remote maintenance, the high caesium consumption. The other key parameter is the gas neutralization concept which minimizes the amount of gas by operating at a low gas target and low neutralizer duct conductance. The implementation of an energy recovery system for the residual 1 MeV D ^− is essential to attain a high wall-plug efficiency. These specific features require thin laminar D ^− beams provided by a pre-acceleration up to 100 keV in slotted grid apertures to form thin blade-like beamlets, followed by the post-acceleration to 1 MeV by merging the beamlets in a single beam in five gaps (+200 kV per gap). All these specific aspects minimize the beams losses and thermal loads along the beamline and enhance the injector reliability and availability.
Keywords