Nature and Science of Sleep (Jul 2024)

Nonlinear Heart Rate Variability Analysis for Sleep Stage Classification Using Integration of Ballistocardiogram and Apple Watch

  • Jaworski D,
  • Park EJ

Journal volume & issue
Vol. Volume 16
pp. 1075 – 1090

Abstract

Read online

Dominic Jaworski,1,2 Edward J Park1,2 1Mechatronic Systems Engineering, Simon Fraser University, Surrey, BC, V3T 0A3, Canada; 2WearTech Labs, Simon Fraser University, Surrey, BC, V3V 0C6, CanadaCorrespondence: Edward J Park; Dominic Jaworski, Surrey Centre 2 Building, 9639 - 137A Street, Unit 206, Surrey, BC, V3V 0C6, Canada, Email [email protected]; [email protected]: Wearable or non-contact, non-intrusive devices present a practical alternative to traditional polysomnography (PSG) for daily assessment of sleep quality. Physiological signals have been known to be nonlinear and nonstationary as the body adapts to states of rest or activity. By integrating more sophisticated nonlinear methodologies, the accuracy of sleep stage identification using such devices can be improved. This advancement enables individuals to monitor and adjust their sleep patterns more effectively without visiting sleep clinics.Patients and Methods: Six participants slept for three cycles of at least three hours each, wearing PSG as a reference, along with an Apple Watch, an actigraphy device, and a ballistocardiography (BCG) bed sensor. The physiological signals were processed with nonlinear methods and trained with a long short-term memory (LSTM) model to classify sleep stages. Nonlinear methods, such as return maps with advanced techniques to analyze the shape and asymmetry in physiological signals, were used to relate these signals to the autonomic nervous system (ANS). The changing dynamics of cardiac signals in restful or active states, regulated by the ANS, were associated with sleep stages and quality, which were measurable.Results: Approximately 73% agreement was obtained by comparing the combination of the BCG and Apple Watch signals against a PSG reference system to classify rapid eye movement (REM) and non-REM sleep stages.Conclusion: Utilizing nonlinear methods to evaluate cardiac dynamics showed an improved sleep quality detection with the non-intrusive devices in this study. A system of non-intrusive devices can provide a comprehensive outlook on health by regularly measuring sleeping patterns and quality over time, offering a relatively accessible method for participants. Additionally, a non-intrusive system can be integrated into a user’s or clinic’s bedroom environment to measure and evaluate sleep quality without negatively impacting sleep. Devices placed around the bedroom could measure user vitals over longer periods with minimal interaction from the user, representing their natural sleeping trends for more accurate health and sleep disorder diagnosis.Keywords: ballistocardiogram, wearable, heart rate variability, nonstationary signals

Keywords