Bioengineering (Aug 2023)

Finite Deformation of Scleral Tissue under Electrical Stimulation: An Arbitrary Lagrangian-Eulerian Finite Element Method

  • Jafar Arash Mehr,
  • Hamed Hatami-Marbini

DOI
https://doi.org/10.3390/bioengineering10080920
Journal volume & issue
Vol. 10, no. 8
p. 920

Abstract

Read online

The sclera is considered as the principal load-bearing tissue within the eye. The sclera is negatively charged; thus, it exhibits mechanical response to electrical stimulation. We recently demonstrated the electroactive behavior of sclera by performing experimental measurements that captured the deformation of the tip of scleral strips subjected to electric voltage. We also numerically analyzed the electromechanical response of the tissue using a chemo-electro-mechanical model. In the pre-sent study, we extended our previous work by experimentally characterizing the deformation profile of scleral strips along their length under electrical stimulation. In addition, we improved our previous mathematical model such that it could numerically capture the large deformation of samples. For this purpose, we considered the transient variability of the fixed charge density and the coupling between mechanical and chemo-electrical phenomena. These improvements in-creased the accuracy of the computational model, resulting in a better numerical representation of experimentally measured bending angles.

Keywords