Frontiers of Architectural Research (Dec 2022)

Thermal comfort analysis of earth-sheltered buildings: The case of meymand village, Iran

  • Amirreza Khaksar,
  • Amir Tabadkani,
  • Seyed Majid Mofidi Shemirani,
  • Aso Hajirasouli,
  • Saeed Banihashemi,
  • Shady Attia

Journal volume & issue
Vol. 11, no. 6
pp. 1214 – 1238

Abstract

Read online

Vernacular buildings are known for their localized passive settings to provide comfortable indoor environment without air conditioning systems. One alternative is the consistent ground temperature over the year that earth-sheltered envelopes take the benefit; however, ensuring annual indoor comfort might be challenging. Thus, this research monitors the indoor thermal indicators of 22 earth-sheltered buildings in Meymand, Iran with a warm-dry climate. Furthermore, the observations are used to validate the simulation results through two outdoor and indoor environmental parameters, air temperature and relative humidity during the hottest period of the year. Findings indicated that the main thermal comfort differences among case studies were mainly due to their architectural layouts where the associated variables including length, width, height, orientation, window-to-wall ratio, and shading depth were optimized through a linkage between Ladybug-tools and Genetic Algorithm (GA) concerning adaptive thermal comfort model definition and could enhance the annual thermal comfort by 31%.

Keywords