Nuclear Technology and Radiation Protection (Jan 2022)

Research on leak monitoring of the primary circuit of a pressurized water reactor based on the 13N coincidence method

  • Zhao Yue,
  • Qu Guo P.,
  • Zhou Jian L.

DOI
https://doi.org/10.2298/NTRP2204308Z
Journal volume & issue
Vol. 37, no. 4
pp. 308 – 314

Abstract

Read online

To assess the characteristics of 13N decay, a monitoring method of the primary loop leakage rate based on the γ-γ coincidence method was proposed. In this work, sampling and measurement devices were designed, in which NaI (Tl) crystals were used as coincidence detectors. The Geant4 simulation method was used to study the relationship between the efficiency e and capacity V change of different devices, and the eV value under the corresponding capacity was obtained. According to the value of eV, the optimal sampling and measurement device was determined, and then the detection efficiency of the device was calibrated experimentally. Taking the 600 000 kW reactor of Qinshan Phase II as the research object, the lower limit of detection was discussed. When the sampling point was located in the fume hood of the control rod drive mechanism, the theoretical lower limit of the coincidence method was 0.756 Lh-1.

Keywords