BMC Pulmonary Medicine (Aug 2018)
Radial probe endobronchial ultrasound using a guide sheath for peripheral lung lesions in beginners
Abstract
Abstract Background The diagnostic yields and safety profiles of transbronchial lung biopsy have not been evaluated in inexperienced physicians using the combined modality of radial probe endobronchial ultrasound and a guide sheath (EBUS-GS). This study assessed the utility and safety of EBUS-GS during the learning phase by referring to a database of performed EBUS-GS procedures. Methods From December 2015 to January 2017, all of the consecutive patients who underwent EBUS-GS were registered. During the study period, two physicians with no previous experience performed the procedure. To assess the diagnostic yields, learning curve, and safety profile of EBUS-GS performed by these inexperienced physicians, the first 100 consecutive EBUS-GS procedures were included in the evaluation. Results The overall diagnostic yield of EBUS-GS performed by two physicans in 200 patients with a peripheral lung lesion was 73.0%. Learning curve analyses showed that the diagnostic yields were stable, even when the procedure was performed by beginners. Complications related to EBUS-GS occurred in three patients (1.5%): pneumothorax developed in two patients (1%) and resolved spontaneously without chest tube drainage; another patient (0.5%) developed a pulmonary infection after EBUS-GS. There were no cases of pneumothorax requiring chest tube drainage, severe hemorrhage, respiratory failure, premature termination of the procedure, or procedure-related mortality. Conclusions EBUS-GS is a safe and stable procedure with an acceptable diagnostic yield, even when performed by physicians with no previous experience.