Arthroscopy, Sports Medicine, and Rehabilitation (Dec 2021)
Significant Improvement in Shoulder Function and Pain in Patients Following Biologic Augmentation of Revision Arthroscopic Rotator Cuff Repair Using an Autologous Fibrin Scaffold and Bone Marrow Aspirate Derived From the Proximal Humerus
Abstract
Purpose: To clinically evaluate patients who underwent a biologic augmentation technique in revision arthroscopic rotator cuff repair using an autologous fibrin scaffold and concentrated stem cells isolated from bone marrow aspirate (BMA) obtained from the proximal humerus. Methods: This is a retrospective review of prospectively collected data from patients who underwent biologic augmentation of revision arthroscopic rotator cuff repair using an autologous fibrin scaffold and BMA obtained from the proximal humerus between 2014 and 2015. Minimum follow-up was 12 months. Outcome measures were collected preoperatively and postoperatively including range of motion as well as American Shoulder and Elbow Surgeons Shoulder Form, Simple Shoulder Test, single assessment numeric evaluation, and visual analog score. In addition, BMA samples of each patient were assessed for the number of nucleated cells and colony-forming units. Regression analysis was performed to investigate whether the number of nucleated cells and colony-forming units had an influence on outcome and failure. Results: Ten patients who underwent biologic augmentation of revision arthroscopic rotator cuff repair using an autologous fibrin scaffold and concentrated BMA obtained from the proximal humerus between 2014 and 2015 were included. The mean follow-up time was 30.7 (range: 12-49) months. Four patients were revised at final follow-up. Postoperative clinical scores improved significantly: American Shoulder and Elbow Surgeons (28.1 ± 5.4 to 60.9 ± 9.0; P < .01), single assessment numeric evaluation (6.6 ± 2.3 to 65.1 ± 10.9; P < .01), visual analog scale (7.2 ± 0.9 to 3.1 ± 0.9; P < .01), and Simple Shoulder Test (1.6 ± 0.5 to 10.3 ± 5.7; P < .01). Postoperative range of motion increased significantly with regard to flexion (97.0 ± 13.6 to 151.0 ± 12.2; P < .01) and abduction (88.0 ± 14.0 to 134.0 ± 15.1; P = .038) but not with external rotation (38.0 ± 5.7 to 50.5 ± 6.5; P = .16). Less pain was correlated to an increased number of nucleated cells (P = .026); however, there was no correlation between failure rate and number of nucleated cells (P = .430). Conclusions: Patients who underwent biologic augmentation of revision arthroscopic rotator cuff repair using an autologous fibrin scaffold and concentrated BMA demonstrated a significant improvement in shoulder function along with reduction of pain. However, the overall revision rate for this procedure was 40%. Level of Evidence: Level IV, therapeutic case series.