With the rising number of older adults residing at home, there is a growing need for risk assessment and patient management in home nursing. This study aims to develop point-of-care test (POCT) reagents that can aid in risk assessment and home care, especially in settings with limited resources. Our focus was on creating a C-reactive protein (CRP) POCT, which can accurately diagnose clinically significant judgment values in home nursing. Additionally, we assessed the utility of the HemoCue WBC DIFF system in providing differential counts of white blood cells (WBC). These performances were compared with a laboratory test using blood samples from patients with pneumonia. The CRP POCT showed a comparable result to that of a laboratory method, with an average kappa index of 0.883. The leukocyte count showed good agreement with the reference method. While the correlation coefficients for both neutrophil and lymphocyte counts were deemed acceptable, it was observed that the measured values tended to be smaller in cases where the cell count was higher. This proportional error indicates a weak correlation with the neutrophil-to-lymphocyte ratio. CRP POCT and WBC counts provided reliable and accurate judgments. These tools may benefit risk management for older adults at home, patients with dementia who cannot communicate, and those living in depopulated areas.