Hospital Practices and Research (Aug 2019)

Cementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report

  • Francesco Castagnini,
  • Giovanni Bracci,
  • Enrico Tassinari,
  • Federico Biondi

DOI
https://doi.org/10.15171/hpr.2019.21
Journal volume & issue
Vol. 4, no. 3
pp. 105 – 108

Abstract

Read online

Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging hardware removal, an iatrogenic subtrochanteric fracture below the degenerated hip occurred after three months. THA with a tapered long stem was successfully performed with no need for additional osteosynthesis, and good results were seen two years later. Discussion: THAs in subtrochanteric fractures are technically demanding but feasible in selected cases. Hardware removal before THA implantation may carry important risks, and the surgical team should be prepared to perform arthroplasty in case of complications. Conclusion: THA in a subtrochanteric fracture below hip osteoarthritis is a feasible option in selected cases.

Keywords