Química Nova (Jan 2012)

A fluorescence-based assay for octreotide in kinetic release from depot formulations

  • Luiz Henrique Guerreiro,
  • Wendell Girad-Dias,
  • Kildare R. de Miranda,
  • Luís Mauricio T. R. Lima

DOI
https://doi.org/10.1590/S0100-40422012000500029
Journal volume & issue
Vol. 35, no. 5
pp. 1025 – 1029

Abstract

Read online

Here we report the validation of a derivatization method that makes use of fluorescamine as a selective reactant for the quantitative analysis of peptide and protein drugs in the dissolution profile from depot formulations. Typical current methods require separation of the nano/microparticles and time-consuming chromatographic runs. In this study we report a method which can be conducted without the need for complete physical separation of the particles or removal of the unreacted probe. This method was used here for the analysis of the release profile of octreotide in a depot formulation, with results in excellent agreement with reported chromatographic assays.

Keywords