Eurasian Chemico-Technological Journal (Dec 2011)
Atomic-Emission Determination of Rhenium in Anthropogenic Raw Materials of Steel Production
Abstract
The method including microwave acidic dissolution of samples and atomic-emission analysis of rhenium for determination of rhenium in cupper-molybdenum and lead-cupper wares is proposed. The range of determination concentration of metal is 0.05 – 0.5 mass percent, standard deviation of repeatability is 0.002 – 0.01%.