Bioengineering (Jun 2023)
Performance of Nuclear Magnetic Resonance-Based Estimated Glomerular Filtration Rate in a Real-World Setting
Abstract
An accurate estimate of glomerular filtration rate (eGFR) is essential for proper clinical management, especially in patients with kidney dysfunction. This prospective observational study evaluated the real-world performance of the nuclear magnetic resonance (NMR)-based GFRNMR equation, which combines creatinine, cystatin C, valine, and myo-inositol with age and sex. We compared GFRNMR performance to that of the 2021 CKD-EPI creatinine and creatinine-cystatin C equations (CKD-EPI2021Cr and CKD-EPI2021CrCys), using 115 fresh routine samples of patients scheduled for urinary iothalamate clearance measurement (mGFR). Median bias to mGFR of the three eGFR equations was comparably low, ranging from 0.4 to 2.0 mL/min/1.73 m2. GFRNMR outperformed the 2021 CKD-EPI equations in terms of precision (interquartile range to mGFR of 10.5 vs. 17.9 mL/min/1.73 m2 for GFRNMR vs. CKD-EPI2021CrCys; p = 0.01) and accuracy (P15, P20, and P30 of 66.1% vs. 48.7% [p = 0.007], 80.0% vs. 60.0% [p p = 0.006], respectively, for GFRNMR vs. CKD-EPI2021CrCys). Clinical parameters such as etiology, comorbidities, or medications did not significantly alter the performance of the three eGFR equations. Altogether, this study confirmed the utility of GFRNMR for accurate GFR estimation, and its potential value in routine clinical practice for improved medical care.