Journal of Cardiovascular Magnetic Resonance (Oct 2011)

Diagnostic Accuracy of Adenosine Stress Cardiovascular Magnetic Resonance Following Acute ST-segment Elevation Myocardial Infarction Post Primary Angioplasty

  • Wong Dennis TL,
  • Leung Michael CH,
  • Das Rajiv,
  • Liew Gary YH,
  • Williams Kerry,
  • Dundon Benjamin K,
  • Molaee Payman,
  • Teo Karen SL,
  • Meredith Ian T,
  • Worthley Matthew I,
  • Worthley Stephen G

DOI
https://doi.org/10.1186/1532-429X-13-62
Journal volume & issue
Vol. 13, no. 1
p. 62

Abstract

Read online

Abstract Background Adenosine stress cardiovascular magnetic resonance (CMR) has been proven an effective tool in detection of reversible ischemia. Limited evidence is available regarding its accuracy in the setting of acute coronary syndromes, particularly in evaluating the significance of non-culprit vessel ischaemia. Adenosine stress CMR and recent advances in semi-quantitative image analysis may prove effective in this area. We sought to determine the diagnostic accuracy of semi-quantitative versus visual assessment of adenosine stress CMR in detecting ischemia in non-culprit territory vessels early after primary percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI). Methods Patients were prospectively enrolled in a CMR imaging protocol with rest and adenosine stress perfusion, viability and cardiac functional assessment 3 days after successful primary-PCI for STEMI. Three short axis slices each divided into 6 segments on first pass adenosine perfusion were visually and semi-quantitatively analysed. Diagnostic accuracy of both methods was compared with non-culprit territory vessels utilising quantitative coronary angiography (QCA) with significant stenosis defined as ≥70%. Results Fifty patients (age 59 ± 12 years) admitted with STEMI were evaluated. All subjects tolerated the adenosine stress CMR imaging protocol with no significant complications. The cohort consisted of 41% anterior and 59% non anterior infarctions. There were a total of 100 non-culprit territory vessels, identified on QCA. The diagnostic accuracy of semi-quantitative analysis was 96% with sensitivity of 99%, specificity of 67%, positive predictive value (PPV) of 97% and negative predictive value (NPV) of 86%. Visual analysis had a diagnostic accuracy of 93% with sensitivity of 96%, specificity of 50%, PPV of 97% and NPV of 43%. Conclusion Adenosine stress CMR allows accurate detection of non-culprit territory stenosis in patients successfully treated with primary-PCI post STEMI. Semi-quantitative analysis may be required for improved accuracy. Larger studies are however required to demonstrate that early detection of non-culprit vessel ischemia in the post STEMI setting provides a meaningful test to guide clinical decision making and ultimately improved patient outcomes.