BioMedical Engineering OnLine (Oct 2021)

Intraoperative serosal extracellular mapping of the human distal colon: a feasibility study

  • Anthony Y. Lin,
  • Chris Varghese,
  • Peng Du,
  • Cameron I. Wells,
  • Niranchan Paskaranandavadivel,
  • Armen A. Gharibans,
  • Jonathan C. Erickson,
  • Ian P. Bissett,
  • Greg O’Grady

DOI
https://doi.org/10.1186/s12938-021-00944-x
Journal volume & issue
Vol. 20, no. 1
pp. 1 – 14

Abstract

Read online

Abstract Background Cyclic motor patterns (CMP) are the predominant motor pattern in the distal colon, and are important in both health and disease. Their origin, mechanism and relation to bioelectrical slow-waves remain incompletely understood. During abdominal surgery, an increase in the CMP occurs in the distal colon. This study aimed to evaluate the feasibility of detecting propagating slow waves and spike waves in the distal human colon through intraoperative, high-resolution (HR), serosal electrical mapping. Methods HR electrical recordings were obtained from the distal colon using validated flexible PCB arrays (6 × 16 electrodes; 4 mm inter-electrode spacing; 2.4 cm2, 0.3 mm diameter) for up to 15 min. Passive unipolar signals were obtained and analysed. Results Eleven patients (33–71 years; 6 females) undergoing colorectal surgery under general anaesthesia (4 with epidurals) were recruited. After artefact removal and comprehensive manual and automated analytics, events consistent with regular propagating activity between 2 and 6 cpm were not identified in any patient. Intermittent clusters of spike-like activities lasting 10–180 s with frequencies of each cluster ranging between 24 and 42 cpm, and an average amplitude of 0.54 ± 0.37 mV were recorded. Conclusions Intraoperative colonic serosal mapping in humans is feasible, but unlike in the stomach and small bowel, revealed no regular propagating electrical activity. Although sporadic, synchronous spike-wave events were identifiable. Alternative techniques are required to characterise the mechanisms underlying the hyperactive CMP observed in the intra- and post-operative period. New findings The aim of this study was to assess the feasibility of detecting propagating electrical activity that may correlate to the cyclic motor pattern in the distal human colon through intraoperative, high-resolution, serosal electrical mapping. High-resolution electrical mapping of the human colon revealed no regular propagating activity, but does reveal sporadic spike-wave events. These findings indicate that further research into appropriate techniques is required to identify the mechanism of hyperactive cyclic motor pattern observed in the intra- and post-operative period in humans.

Keywords