Energies (Jan 2021)

A Comparative Study of the Scale Effect on the S-Shaped Characteristics of a Pump-Turbine Unit

  • Jun-Won Suh,
  • Seung-Jun Kim,
  • Hyeon-Mo Yang,
  • Moo-Sung Kim,
  • Won-Gu Joo,
  • Jungwan Park,
  • Jin-Hyuk Kim,
  • Young-Seok Choi

DOI
https://doi.org/10.3390/en14030525
Journal volume & issue
Vol. 14, no. 3
p. 525

Abstract

Read online

S-shaped characteristics in turbine mode are prone to instabilities in associated transient processes. A single value of the speed factor corresponds to multiple values of the discharge factor, having the possibility of changing the operating point among the turbine, turbine brake, and reverse pump modes. Because of this characteristic, the S-shaped curves induce instability in transient processes. Understanding the hydraulic behavior of a turbine on the four-quadrant characteristic is important since it provides detailed performance information through the whole discharge range of the turbine. This study was numerically and experimentally investigated the scale effect on the S-shaped characteristics in the turbine transition region. The four-quadrant characteristic curves (full- and laboratory-scale) in the turbine mode were predicted by numerical simulations. To verify the predicted results, a laboratory-scale experiment was performed in the turbine, turbine brake, and reverse pump modes. Although the full-scale experiment was performed in the normal operating head range, the scale effect can be validated by comparing steady operating points between the two models. Based on the verified results, the internal flow and pressure pulsation characteristics were determined at the operating point in a specific transition region.

Keywords