MATEC Web of Conferences (Jan 2016)
Advanced Hygrothermal Performance of Building Component at Reconstruction of S. Radonezhskiy Temple in Volgograd
Abstract
The paper presents new thermal design of external wall S. Radonezhskiy temple in Volgograd is developed according to author’s concept. The three-layer brick wall, including a thermal insulation layer from concrete with polystyrene aggregates, is considered. Calculation of interstitial condensation in building component is carried out according to simplified calculation method developed by the author and harmonized to ISO 13788. Analysis of calculation results shows that condensation occurs at one interface during some months but there is no accumulation over the year as all the condensate is predicted to evaporate again. Thus, there is no systematic moisture accumulation at the building component within a year. The risk of run-off from non-absorbent materials will be very low. Analysis of the evaporation rates at the interface shows that duration of drying wetted layer in external wall during initial stage does not exceed admissible values.