Iranian Journal of Medical Physics (Jun 2017)

The Impact of Residual Geometric Inaccuracies on Normal Organ Doses in Image Guided-Radiation Therapy of Prostate Cancer Using On-Board Kilovoltage Cone-Beam Computed Tomography

  • Asghar Mesbahi,
  • Dogukan Akcay,
  • Ismail volkan Tekcan,
  • Zumre Arican Alikus

DOI
https://doi.org/10.22038/ijmp.2017.19419.1178
Journal volume & issue
Vol. 14, no. 2
pp. 104 – 113

Abstract

Read online

Introduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomography (CBCT) images were taken after bony anatomy alignment by using two orthogonal radiographic images, as well as CBCT images. Dose distributions and dose volume histograms (DVH) for all the original and CBCT plans were obtained. Maximum, as well as mean doses and volumes of the bladder, rectum, and both femoral heads were recorded for each CBCT plan and compared with the original CT plan. For all the studied body parts, the differences in DVH between CBCT plans and original CT plan were calculated and compared. Results: Considering all the 75 CBCT images for the 15 patients, average of changes in mean doses and volumes were 17.8%, 41.8%, 7.1%, and 36.8% for the bladder and rectum, respectively. There was a significant (P

Keywords