Sulaimani Journal for Engineering Sciences (Aug 2021)

Experimental Work on Using Fully Wrapped Post-Tensioned Metal Straps Around Normal Reinforced Concrete Beams to Increase Flexural Strength of R.C Beams

  • Wrya Abdullah,
  • Avesta Omar,
  • Serwan Khwrshid Rafiq

DOI
https://doi.org/10.17656/sjes.10147
Journal volume & issue
Vol. 8, no. 1
pp. 50 – 62

Abstract

Read online

To increase the capacity load carrying of the beams, post tensioned metal straps are fully wrapped around the beams in their tensile zone in this study. In total four normal R.C beams with the depth of 160 mm, height of 240 mm and total length of 2100 mm are cast and tested under four-point load testing. The number of variables is kept to minimum of two which are the number and location of the straps. It is found that using post tensioned metal straps fully wrapped around the beams can increase the loadcarrying capacity of the beams by 36% at least and 39% at a max. The main factor in influencing the rate is the location of the straps. A complete guide on using the material along with its application on the beams are explicitly described in the paper.

Keywords