IET Electric Power Applications (Sep 2021)

A secure and sensitive wavelet transform based technique for stator fault detection in the cases of line‐connected and inverter‐fed induction machines

  • Mohammad Hossein Nazemi,
  • Davar Gallehdar,
  • Farhad Haghjoo,
  • Sérgio Cruz

DOI
https://doi.org/10.1049/elp2.12084
Journal volume & issue
Vol. 15, no. 9
pp. 1138 – 1153

Abstract

Read online

Abstract Here a new sensitive fault detection criterion is proposed, based on the stationary wavelet transform (SWT) decomposition components of the stator currents, for the online detection of stator winding turn‐to‐turn faults at an early stage of development. The energies of the desired detail components are calculated and the normalized Euclidean distance of the energy differences between the three phases is used as a new fault detection criterion. The robustness of the proposed technique against the presence of rotor turn‐to‐turn faults and loading variations is demonstrated. In addition, an adaptive threshold level as a function of the voltage unbalance factor is proposed to guarantee the robustness of the diagnostic technique against unbalanced voltage sources. Experimental results demonstrate the effectiveness and sensitivity of the proposed diagnostic approach for the detection of stator faults in line‐connected and inverter‐fed motors.