Ophthalmology and Therapy (Mar 2024)
Effect of Intraorbital Mechanical Compression on Retinal Microvascular Perfusion in Quiescent Thyroid-Associated Ophthalmopathy Based on Ocular Biomechanics Measured by Corvis ST
Abstract
Abstract Introduction To analyze the correlation between orbital compliance and retinal vessel density (VD) based on dynamic Scheimpflug analyzer (Corvis ST) and optical coherence tomographic angiography (OCT-A). Methods In this prospective observational study, 65 eyes of 44 patients with thyroid-associated ophthalmopathy (TAO) in quiescent stage were included (15 males and 29 females). The whole eye movement (WEM) was detected by Corvis ST. The superficial capillary plexus VD (SCP-VD) and deep capillary plexus VD (DCP-VD) were obtained by scanning the 3 × 3 mm area around the fovea using OCT-A, while the peripapillary vessel density (ppVD) was obtained by scanning the 4.5 × 4.5 mm area around the optic disk. Covariances including biomechanically corrected intraocular pressure (bIOP), axial length, age and gender were adjusted during data analysis. Results The mean WEM of the participants was 0.235 ± 0.066 mm. The mean SCP-VD and DCP-VD in whole image were 46.20% ± 3.77% and 50.51% ± 3.96%; the mean whole pp-VD was 49.75% ± 2.01%. WEM was positively correlated with SCP-VD (r = 0.327, p = 0.01) and the whole pp-VD (r = 0.394, p < 0.01) after adjusting by gender, axial length (AL), age and bIOP, but it was not significantly correlated with DCP-VD (r = 0.072 p = 0.581). Conclusion Increase in orbital pressure might reduce retinal microvascular perfusion. Our data suggest orbital mechanical compression may be an important cause of retinal VD changes in quiescent patients with TAO.
Keywords